Islanding and Anti-Islanding Protection

Updated 2026-08-24 · Read this page as Markdown

Islanding is the dangerous condition in which a grid-tied inverter keeps energising a section of the network after the utility supply has failed. Anti-islanding protection is the mandatory function that detects this and disconnects the inverter within a fraction of a second.

The hazard is concrete: a line crew expects a de-energised circuit, and an inverter still feeding it could injure them, while reconnection out of phase can damage equipment. Detection combines passive monitoring of voltage and frequency limits with an active method that gently perturbs the output and watches whether the grid pushes back. The practical consequence for homeowners is the one that surprises them most — a standard grid-tied system stops producing during a blackout even in bright sunshine. Backup requires a hybrid or off-grid inverter with a transfer arrangement that isolates the house first.

Advertisement

Related terms

Arc-Fault Detection (AFCI) A protective function that monitors the DC circuit for the electrical signature of an arc caused by a damaged conductor or a loose connection, and shuts the inverter down when it detects one. It is required on PV DC circuits above a defined voltage in several jurisdictions. Curtailment (export limiting) The deliberate reduction of an inverter's output below what the array could deliver, in order to respect an export limit set by the network operator. Zero export means the system is curtailed whenever generation exceeds on-site demand. Feed-In / Export The energy a PV system sends to the public grid when generation exceeds on-site demand. It is measured by a bidirectional meter and remunerated or netted according to the local regulatory scheme. Grid Code The set of technical rules a distributed generator must comply with to connect to the public network, covering voltage and frequency operating limits, power quality, protection settings and required responses to grid disturbances. Inverters are certified against specific national grid codes. Rapid Shutdown A safety requirement that the DC conductors of a rooftop PV array be brought down to a low, touch-safe voltage quickly once an initiator is operated, so firefighters and maintenance staff can work on the roof. It is enforced by module-level or string-level shutdown devices. Residual Current Monitoring (RCD / RCMU) The detection of leakage current flowing to earth rather than returning through the intended conductor, which indicates an insulation fault and a possible shock hazard. Transformerless PV inverters include an internal residual current monitoring unit sensitive to both AC and DC leakage.
Advertisement