Derating

Updated 2026-08-24 · Read this page as Markdown

The automatic reduction of an inverter's output power to protect its internal components, most commonly triggered by high temperature but also by high grid voltage or by an out-of-range input. The unit keeps running at reduced capacity instead of shutting down.

Thermal derating is the usual case: once ambient temperature climbs past the manufacturer's threshold, output falls progressively, and it does so on exactly the hot, clear afternoons when the array is producing hardest. Mounting on a shaded, ventilated north-facing wall — south-facing in the southern hemisphere — and respecting the specified clearances often recovers more annual energy than choosing a nominally more efficient model. Grid-voltage derating is the other frequent cause and points at a different problem: a long or undersized AC cable run pushing the voltage at the inverter terminals towards its upper limit.